Electrical Connection (Required) - Travis Industries 21 TRV GSR2 Installation Manual

Hide thumbs Also See for 21 TRV GSR2:
Table of Contents

Advertisement

Electrical Connection (required)

The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified
installer and must meet all local codes.
Make sure the household breaker is shut off prior to working on any electrical lines.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps).
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
Caution:
improper and dangerous operation.
Remove the cover from the
a
fireplace junction box.
Travis Industries
Installation
(for qualified installers only)
Remove the knock-out from the cover plate.
c
Secure the romex connector to the cover plate. Route
d
the electrical line through the cover plate and attach the
electrical leads. Replace the cover plate.
The connection wires and a romex clamp
b
are inside the junction box.
NOTE: An alternative knock-out is
provided in the base of the
fireplace if you wish to run the
electrical line from below.
4150309
23
100-01421