Framing Dimensions - Regency Horizon HZ30E-NG10 Owners & Installation Manual

Horizon hz30e series gas fireplace
Hide thumbs Also See for Horizon HZ30E-NG10:
Table of Contents

Advertisement

installation
|
14
NOTE: If not purchasing the optional steel stud kit - adhere to the same framing if purchasing steel studs elsewhere. The use of the optional kit is highly
recommended as it was designed specifically for the product to facilitate ease of installation.
Framing
Dimensions
A
B
*
C
D
E
F
G
H
I
J
K
L
*
Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible.
The nailing strips can be adjusted back up to 3-1/8" to allow for varying thicknesses in non-combustible
material & wall finishes.
Note: All other framing may
be of wood construction.
Note: T
wo
horizontal
steel studs must be
installed after the unit is in
position and the venting,
gas and electrical is
,
installed. The horizontal
studs allow the non-
combustible wall board to
be attached and
supported.
D
14 |
Regency Horizon HZ30E-10 Gas Fireplace

FRAMING DIMENSIONS

Description
Framing Height
Framing Width
*
Framing Depth
Minimum Height to Combustibles
Corner Wall Depth
Corner Facing Wall Width
Vent Centerline Height
Non-combustible facing height
Gas Connection Opening Height
Gas Connection Height
Gas Connection Inset
Gas Connection Opening Width
Metal Stud
on edge
A
B
Finished Floor
F
33-5/16" (946mm)
31 - 3/16" (792mm)
C1
Horizontal Vent 15" (381mm)
C2 Vertical Vent, vertical rise - terminating horizonally - 21-1/4" (540mm)
Rigid 35-1/2" (902mm) | Flex 32-7/8" (835mm)
43-5/16" ( 1100mm)
61-1/4" (1556mm)
Rigid 29-1/4" (743mm)
Flex 26-5/8" (676mm)
13-1/4" (367mm)
3-1/4" (83mm)
4-1/8" (105mm)
3-1/2" (89mm)
Metal Stud (Header)
G
C1
C
C2
I
L
K
HZ30E
2" (51mm)
Drywall or
other facing
H
Non-Combustible
Facing
J

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon hz30e-lp10Horizon hz30e

Table of Contents