Clearances - Regency Horizon HZ30E-NG10 Owners & Installation Manual

Horizon hz30e series gas fireplace
Hide thumbs Also See for Horizon HZ30E-NG10:
Table of Contents

Advertisement

installation
|
10
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance
that this fireplace and vent system be installed only in accordance with these instructions.
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
Clearance:
A: Sidewall (on one side)
B: Ceiling
(room and/or alcove)
C: Mantel Height (min.)
D: Mantel Depth (max.)
E: Alcove Width
F: Alcove Depth
G: From Floor
Note:
D
G
10 |
Regency Horizon HZ30E-10 Gas Fireplace

CLEARANCES

Dimension
Measured From:
8" (203mm)
Side of Fireplace Opening
39" (991mm)
Top of Fireplace Opening
13-1/4" (330mm)
Top of Fireplace Opening
21-1/4" Above Fireplace
12" (305mm)
Opening
60" (1524mm)
Sidewall to Sidewall (Minimum)
36" (914mm)
Front to Back Wall (Maximum)
21" (533mm)
Top of Fireplace Opening
0"
F
A
E
Installed Close
to Floor
F
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
No hearth required
B
Unit
E
Alcove
WARNING
Fire hazard is an extreme risk
Flue Clearances to Combustibles
Horizontal - Top
Horiztonal - Side
Horiztonal - Bottom
Vertical
Passing through wall/
floor/ceiling - when
firestop is used.
A
3"
2"
2"
2"
1-1/2"