Framing Dimensions - Regency City Series New York 72 Manual

Table of Contents

Advertisement

Framing Dimensions

NOTE: Framing may be constructed of combustible material (ie. 2 x 4)and does not require steel studs.
Framing
Description
Dimensions
A
Framing Height
B
Framing Width
C
Framing Depth
D
Minimum Height to Combustibles
E
Corner Wall Depth
F
Corner Facing Wall Width
G
Vent Centerline Height
I
Gas Connection Opening Height
J
Gas Connection Height
K*
Gas Connection Inset-Centre Opening
L
Gas Connection Opening Width
* See next page for alternate Gas/ Electrical connection options
With the lift handles adding approximately 4 inches to the overall width of the appliance. In cases where the appliance would need to be raised off the ground
in order to slide it into the framed opening, it is suggested that either the framing width change from 78" to 82" so that the appliance could be easily slid
into position with the handles remaining on the appliance, or alternatively create a platform in front of the framed opening where the lift handles could be
removed prior to sliding the appliance into its final position. Alternatively, If raised off the ground, the framing could be installed afterwards once appliance
has been put into place and lift handles removed in order to keep the framing width at 78". Ensure that the wood base that the appliance will sit on is strong
enough to support the full weight of this appliance. The overall weight of this appliance is 529 pounds (shipping weight).
Note: A combined minimum of
288 square inches of open area
is required for the convection
air outlet to cool the enclosure.
Ensure clearances for Convec-
tion Air Outlets are met.
See clearances CV72E in this
manual as there are different
methods as to how this can
be achieved.
Note: Wood studs in back
can be either wood 2'' x 4''
or 2'' x 6''.
Note: This appliance must be
installed on a solid surface
such as a plywood floor which
must be the full width and
depth of the appliance.
CV72E
51" (1295mm)
78" (1981mm)
20-5/8" (524mm)
87"(2210mm)
82-1/8" (2086mm)
116-3/16" (2951mm)
55-1/4" (1403mm)
2" (51mm)
3-7/8" (98mm)
36-1/4" (921mm)
5" (127mm)