Sequential Scan Setup [470]

The following procedures are only available when the AV Codec is set to TRANSMITTER in the [100 MODE] menu.
This menu lets you enable or disable sequential monitoring of view points (1 to 8) at the remote site. This function is available
in a standby state and during communication.
4 7 0
S E Q . S C A N
S E Q . S C A N
D W E L L
T I M E
R E S T A R T
T I M E :
↑ ↓ ← →
: M O V E

Alarm Memory Method Setup [480]

The following procedures are only available when the AV Codec is set to TRANSMITTER in the [100 MODE] menu.
This menu lets you set the alarm storage method in the codec at the remote site when an alarm is received from an associated
alarm sensor.
4 8 0
V I D E O
M E M O R Y
A L A R M
M E M O R Y :
← → :
S E L E C T
Storage pre and post frames
When PRE/POST is set for this item, no alarm dialing
takes place till the alarm storage is over after the alarm
input.
51
Transmitter
S E T U P
:
O N
O F F
:
. . S
( 0 2 S - 3 0 S )
. . 0 S
( 0 1 0 S - 3 0 0 S )
E S C : P R V
P R E / P O S T
P R E
O N L Y
E S C : P R V
Move the cursor to the SEQ. SCAN parameter.
1
Then select either ON or OFF by pressing the
Direction buttons.
ON:
Enables sequential scan.
OFF:
Disables sequential scan.
2
Move the cursor to the DWELL TIME
parameter. Then enter a specific time by
pressing the numeric buttons.
This item lets you set the length of time that is monitored at
each view point.
It can be specified from 2 to 30 seconds in 1-second incre-
ments.
Move the cursor to the RESTART TIME
3
parameter. Then enter a specific time by
pressing the numeric buttons.
This item lets you set the restart time to return to sequential
scan when a view point is manually controlled during a
scan.
It can be specified from 10 to 300 seconds in 10-second
increments.
* Pre and Post frame
A pre-frame is a frame stored in the memory during stand-
by state or prior to input of the alarm.
A post-frame is a frame stored in memory after an alarm
input.
Move the cursor to the ALARM MEMORY
1
parameter. Then select either mode by
pressing the Direction buttons.
PRE/POST: Enables storage of pre and post frames (video
and audio).
About 20-seconds of pre-frames and 20-seconds of
post-frames can be stored.
PRE ONLY: Enables storage of about 40-seconds of pre
frames only (video and audio).
Storage Time
The storage time differs between 30-seconds and 40-
seconds depending on the movement or intricacy of
the objects.
Similarly it may be less than 20-seconds for pre and
post frames.