Flx Power System Dpr-2700 - Barco FLX-60 Installation Manual

Table of Contents

Advertisement

3. Components of an FLX display system
3.6

FLX power system DPR-2700

Introduction
The FLX Power System DPR-2700 consists of a chassis with two DC distribution shelves of three modular FLX Power Rectifier DPR-
2700 units and a Control and Supervisory Unit (CSU). The FLX Power Rectifier DPR-2700 units are some times refer to as "SMR"
(Switch Mode Rectifier). The FLX Power System DPR-2700 requires a nominal three phase AC input of 230V (delta connection) or
400V (star connection), 50-60Hz.
The rear side of the power chassis has two power output ports (multi pole sockets) which provide in 16 (2 x 8) protected circuits with
a DC output of -54V.
One power output port of the FLX Power System DPR-2700 can power maximum 2048 FLX-60 pixels. The FLX Power System
DPR-2700 has two power output ports, so one FLX Power System DPR-2700 can power maximum 4096 FLX-60 pixels. This large
number of pixels can only be powered in case the total length of the power cables, from the power output port to the last FLX-60 pixel
in the connector string, is limited. Otherwise, the voltage drop over the power cables will be too high and because of this disabling
the last FLX-60 pixels in the string.
Image 3-25
FLX Power Chassis DPR-2700 without rectifiers (R9899431)
Refer to the manual of the FLX Power System DPR-2700 for more information about installation and usage
guidelines.
Parts location
1
2
Image 3-26
1
Control and Supervisory Unit (NCSU).
2
Removable FLX Power rectifier DPR-2700.
3
Female multi pole power output sockets.
4
Cable gland for the mains input power cable.
FLX Power Rectifier DPR-2700
The FLX Power System DPR-2700 contains 6 removable (not hot swappable) FLX Power Rectifier DPR-2700 units. One rectifier
can deliver 2700 Watt (50 ampere DC). In case a rectifier fails, the other rectifiers remain delivering there maximum power. For
video applications with typical video content the FLX Power System DPR-2700 will run at average 30-40% of its maximum. So, in
case a rectifier fails it will probably not be visible during the event. The malfunction rectifier can be replaced after the event.
34
3
4
R59770419 FLX-60 12/05/2010