The transfer characteristics of most cameras and displays are nonlinear. For a display, a small change in amplitude
when the signal level is small produces a change in the display brightness level, but the same change in amplitude at a
high level will not produce the same magnitude of brightness change. This nonlinearity is known as gamma. Different
gamma curves are available to compensate the nonlinearity.
See user guide of the Director toolset to learn more about Gamma curves.
BARCO FLX ► This controller ► Info
Info page 1
Barco FLX, This controller, Info (1/3)
Address:
3
Ctrl serial :
Board serial:
Input(HxV): 1632x616
Info page 2
Barco FLX, This controller, Info (2/3)
VERSIONS:
SoftWare:
1.0.0
FirmWare:
1.0.0
CPLD: 1.3
Info page 3
Barco FLX, This controller, Info (3/3)
OUT 1:
OK
OUT 2:
OK
OUT 3:
OK
OUT 4:
OK
BARCO FLX ► This controller ► Address
BARCO FLX
This controller
Address:
12
Address:
12
BARCO FLX ► This controller ► LCD contrast
BARCO FLX
This controller
LCD contrast:
Address:
12
R59770419 FLX-60 12/05/2010
G3
G4
D1
D2
D3
► Back
Temperature:
36°C
<zzzzzzzzzzzz>
<xxxxxxxxxxxxxxxxxx>
►Continue
Backup SW: 1.0.0
Backup FW: 1.0.0
►Continue
OUT 5:
NC
OUT 6:
NC
OUT 7:
OK
OUT 8:
OK
►Continue
► Up 10
Up 1
Down 1
Down 10
Back
► Up 10
Up 1
45
Down 1
Down 10
Back
3. Components of an FLX display system
The arrow ▼, in the lower right corner, which is pointing
downwards indicates that the list is longer than the LCD display.
Use the navigation buttons to scroll down to see the next items in
the list. An arrow ▲ in the upper right corner will appear.
The last item in the list is 'Back' which can be used to go to the
previous menu.
This menu displays information about this FLX-NNI Controller.
This menu has three pages. The first page shows the address,
temperature, serial number of the FLX-NNI Controller, serial
number of the internal circuit board and the horizontal and vertical
resolution of the incoming data stream (IN) from the digitizer.
Press the select button to go to the next page (Continue).
The second page of the info menu shows all the software/firmware
versions of this FLX-NNI Controller.
The third page of the info menu shows the status of all eight
data output ports of this FLX-NNI Controller. 'OK' means that
an FLX-HUB is connected with the output port. 'NC' means that
no FLX-HUB was found.
This menu allows you to set the address of this FLX-NNI
Controller. The address can be set per step or per 10 steps. The
lowest address number is 0, the highest is 32767. Note that the
address number 0 is reserved for broadcasting. Each FLX-NNI
Controller is listening to the broadcast address 0 and to its own
address. So, it's recommend to start the address numbering from
1 or higher.
This menu allows you to set the LCD contrast of this FLX-NNI
Controller. The LCD contrast can be adjusted between 0 and
255 in steps of 1 or 10.