Closing the CK30

CK30 Handheld Computer Service Manual
Insert a new tethered scanner door and snap it in place.
b
6 Insert a new tethered scan flex assembly into the mounting bracket and
attach it with the two screws removed in Step 4.
7 Insert the tethered scan flex assembly into the bottom cover and attach
it with the four screws removed in Step 2.
8 Close the CK30. For help, see the next procedure, "Closing the CK30."
To close the CK30, you need the following tools:
• T10 Torx screwdriver
• Small Phillips screwdriver
• Phillips 2-56 x .312 screw (P/N 590371-001)
• Torx 4-40 x .25 machine screw (P/N 590870-001)
• Torx 4-20 x .625 self-tapping screw (P/N 590872-001)
• Phillips flathead 4-40 x .875 screw (P/N 591882-001)
To close the computer
1 Connect the trigger reed switch cable to J4 on the main PCB.
2 Connect the scanner or imager flex cable to the main PCB. Make sure you
completely insert the scan flex cable up to the white alignment mark.
3 Carefully close the top and bottom covers. Make sure that the cables are not
pinched between the two covers.
Chapter 2 — Replacing Parts
Tethered
scanner
door
27