Replacing the SE1200 Scanner

CK30 Handheld Computer Service Manual
Keypad
assembly
Keypad
flex
cable
4 Remove the adhesive residue left by the keypad assembly on the top
cover.
5 Remove the adhesive backing from the new keypad assembly.
Keypad
assembly
Adhesive
backing
6 Connect the keypad flex cable to the keypad assembly and firmly attach
the keypad assembly to the top cover. Make sure the keypad flex cable
properly z-folds under the main PCB.
7 Insert a new bezel assembly. For help, see "Replacing the Bezel
Assembly" on page 17.
To replace the SE1200 scanner, you need the following tools:
• T10 Torx screwdriver
• Small Phillips screwdriver
You also need one or more of the following parts depending on what you
need to replace:
• SE1200 standard range scan engine assembly (P/N 590014-004)
• SE1200 advanced long range scan engine assembly (P/N 591098-003)
• SE1200 CK30 scan flex cable (P/N 072781-003)
• SE1200 shield (P/N 073883-002) (if necessary)
• SE1200 visor (P/N 073703-003)
• Large scan mount bracket (P/N 072865-002)
• M2 x 0.4 by 4mm steel panhead screw (P/N 800-318-004)
• Phillips 2-28 x .250 thread-form screw (P/N 525301)