Chapter 2 — Replacing Parts
26
You also need one or more of the following parts depending on what you
need to replace:
• Tethered scan flex assembly (P/N 072786-004)
• Tethered scanner door (P/N 073366-001)
• Tethered scanner cover (P/N 073179-001)
• Phillips 2-56 x 3/16 steel screw (P/N 591884-001)
• Phillips 2-28 x .250 thread-form screw (P/N 525301)
To replace the tethered scanner
1 Open the CK30. For help, see "Opening the CK30" on page 9.
2 From the bottom cover, remove the four Phillips screws that attach
the tethered scan flex assembly.
3 Work the tethered scanner connector loose from the scan window
and lift the tethered scan flex assembly away from the bottom cover.
4 Remove the two Phillips screws that attach the tethered scan flex
assembly to the mounting bracket.
5 If you need to replace the tethered scanner door:
Use a straight-slot screwdriver to pry loose one of the lower tabs from
a
the bottom door and push it out of the opening in the bottom cover.
Screw
(4 places)