TEC B-470 SERIES Maintenance Manual page 41

Thermal printer
Table of Contents

Advertisement

6. DIAG. TEST OPERATION
Sample Print
[Print Condition]
• Preset count
• Print speed
• Sensor
• Printing method :
• Supply length
• Issuing mode
1) Maintenance Counter
#
Item
(1)
Total media distance
covered
(2)
Media distance covered
(3)
Print distance
(4)
Cut count
(5)
Head up and down count
(6)
Ribbon motor driving time
(7)
Solenoid driving time
(8)
RS-232C hardware error
count
(9)
System error count
(10)
Momentary power failure
count
NOTES: 1. Item from (2) through (10) are initialized to "0" after RAM clear.
2. If the distance is 8.2 m or less, it is rounded down and no data is added to the memory at
power off.
3. If the count is 31 counts or less, it is rounded down and no data is added to the memory at
power off.
4. If the driving time is 32 sec. or less, it is rounded down and no data is added to the memory
at power off.
5. When a sent command results in an error, the same number as the data capacity of the
command is counted by byte.
:
1
:
6"/sec.
:
No sensor
Thermal transfer
:
50 mm
:
Batch printing
(without rewinder)
Counted when the feed motor drives to feed, print and issue the
media. (Counted also during ribbon save operation and back
feed.) [See NOTE 2.]
Counted while printing. (Feeding and issuing media, and ribbon
saving operation are not counted.) [See NOTE 2.]
Counts every cut. [See NOTE 3.]
Counts every up and down of the print head using the solenoid
for ribbon save operation. (Up+Down=1 count) [See NOTE 3.]
Counts when the ribbon motor drives to feed, print and issue the
media. (The driving time is not counted during ribbon saving
operation, but is during back feed.) [See NOTE 4.]
Counted during ribbon saving operation. [See NOTE 4.]
Counted when a parity, overrun or framing error occurs. [See
NOTE 5.]
Counted when a zero-dividing error occurs or undefined command
is retrieved.
Counts the number of times the power restores while the CPU is
busy after reset.
(1)
TL FEED
1882.3km
(2)
FEED
20.5km
(3)
PRINT
15.0km
(4)
CUT
148150
(5)
HEAD U/D 170
(6)
RIBBON
32h
(7)
SOLENOID 0h
(8)
232C ERR 1
(9)
SYS ERR 0
(10)
PW FAIL 0
(11)
FONT [PC-850] [0]
(12)
CODE [ESC LF NUL]
(13)
RIBN [TRANS.]
(27)
RIBN ADJ. [PC] +0 +0 [KEY]+0 +0
(28)
STATUS [OFF]
(25)
THRESHOLD R1.0V
(26)
THRESHOLD T 1.4V
(29)
KANJI [TYPE1]
(30)
MOTOR [TYPE2]
(31)
EURO CODE B0H
(32)
DTR/RTS [DTR]
(33)
INPUT PRIME [ON]
Count Condition
6-4
EM18-33011
(Revision Date: Dec. 10 '99)
6.2 SELF TEST MODE
[PC]
FEED
+10.0mm
CUT
-5.0mm
BACK
+3.0mm
TONE(T)
+3step
TONE(D)
+5step
[KEY]
FEED
+5.0mm
CUT
-1.5mm
BACK
+0.5mm
TONE(T)
+0step
TONE(D)
+1step
X ADJ.
+35.0mm
Fig. 6-1
Range
0.0 ~ 3200.0
km
0.0 ~ 200.0 km
0.0 ~ 200.0 km
0 ~ 1000000
times
0 ~ 2000000
times
0 ~ 2000 hours
0 ~ 1000 hours
0 ~ 255 times
0 ~ 15 times
0 ~ 15 times
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents