2. MAJOR UNIT REPLACEMENT
EM18-33011
2.5 Replacing the Solenoid
NOTE: Make sure to remove any dust that appears during removal or installation because it may affect
the print quality.
4) Replace the solenoid and attach it to the solenoid attaching plate.
5) Assemble the solenoid unit so that the head up link engages the spring pin.
Solenoid
Spring Pin
Head Up Link
Fig. 2-12
CAUTION: Take care to orient the screw so that they are vertically aligned with the solenoid
attaching plate.
6) Reasemble in the reverse order of removal.
2-7