TEC B-470 SERIES Maintenance Manual page 30

Thermal printer
Table of Contents

Advertisement

3. INSTALLATION PROCEDURE FOR THE OPTIONAL EQUIPMENT
8. Connect the shorter harness of the strip sensor (Tr) with the strip sensor harness (LED).
9. Pass the other the strip sensor (Tr) harness through the clamp and connect to CN6 on the CPU PC
Board.
10. Secure the strip sensors (Tr) and (LED) with SM-4 x 6B screw.
11. Fix the harness mentioned in Step 7 with the clamp. Be sure to wire the harness along with the main
frame, base and right plate.
12. Reassemble the operation panel, top cover and left side cover in the reverse order of removal.
13. Set the DIP SW 1-6 to ON.
14. When using the built-in rewinder in Batch mode, fit the rewinder guide plate to the strip shaft, then
attach it with the black screws which were removed in step 4.
CPU PC Board
Connector (CN6)
Harness
Clamp
Strip Sensor (Tr)
Harness
3-10
3.5 Strip Module (B-4905-H-QM)
Main Frame
Strip Sensor (LED)
Screw (SM-4x6B)
EM18-33011
Base
Right Plate
Fig. 3-13

Hide quick links: