OfficeServ 7200
TECHNICAL MANUAL
OFFICESERV 7150 REAR VIEW
Rear view of the cabinet contains an external battery connection port, a power connector, a
DC output connection port and a grounding port.
AC Power
Connection
PARTS
The Offiserv 7150 cabinet (KP-OSDBRES/XAR) comes with the following parts:
• PoE Cable 1 each
• Battery cable 1 each
• AC Power cable(110V Type) 1 each
• Alarm cable 1each (not used for OfficeServ 7200 systems)
• 19" Rack mount kit 1set
The POE-M PSU modules are sold separately. Extra PoE cables can be purchased if needed.
OFFICESERV 7150 INSTALLATION
Safety Conditions
•
Follow all site requirements listed in section 1.1.1.
•
Before installing OfficeServ 7150 PoE, check electric cable connection, grounding,
voltage and frequency status.
•
The building where OfficeServ 7150 PoE is installed should be protected properly against
lightning and electric leakage using arresters or grounding.
•
OfficeServ 7150 PoE must be mounted on a leveled surface or rack..
•
Keep the OS7150 away from static electricity.
•
Input power of OfficeServ 7150 PoE should be AC 88~264V. Do not use the system with
motors or compressors.
Temperature/Humidity Conditions
Following environmental conditions should be maintained:
•
Operating Temperature : 32º~113ºF
•
Storage Temperature : 14º ~ 122ºF
•
Humidity : 10~90%
The system should be installed at a cool, dust-free place without direct sun light and proper
air ventilation.
Figure 5.5 Rear View of OS 7150 Cabinet