3-4-3. Crispening Adjustment

Equipment: Waveform monitor (R, G, B)
Test Point: SDI connector
Object:
Grayscale chart
Preparations
. Setting for MSU-900
DETAIL OFF button → ON (dark)
. Shoot the grayscale chart so that the chart frame is
aligned with the underscanned monitor frame.
. Iris of the lens: A = 600 ?20 mV
Adjustment Procedure
1. Perform the automatic white balance adjustment.
WHITE button/MSU-900 → ON (lit)
2. Adjust the crispening level.
MSU menu operation:
. PAINT button→ ON (lit)
. Touch panel operation
(Page 1/3) → [Detail] → [Detail|1]
Adjustment item: Crispening
Specifi cation:
Set Crispening to -99 once, and
turn slowly for increment until
the noise at the black level of the
waveform just decreases. Or
adjust for the desired level.
HXC-100/V1 (E)
A
3-17