6-1. Preparations

6-1-1. Equipment Required

. SD waveform/vector monitor
. Analog HD waveform monitor
. Oscilloscope:
Tektronix TDS460A or equivalent
. Frequency counter:
Advantest TR5821AK or equivalent
. Audio oscillator:
Tektronix SG-5010 or equivalent
. Audio analyzer
. FM signal generator: ROHDE & SCHWARZ SMHU58 or equivalent
Related equipment
. HD color camera HXC-100
. Remote control panel RCP-750/751
Tools
Sony Part No.
Name
A-1727-365-A
Extended board EX-1121
A-1727-367-A
Extended board EX-1098
A-1727-368-A
Extended board EX-1099
A-1727-369-A
Extended board EX-1100

6-1-2. Precautions on Adjustments

. Warm up the unit for about 10 minutes before starting adjustments.
. All measuring equipment must have been calibrated.
. "Section 6-1-4. Initial Settings" must have been completed.
. Adjustments for HXC-100 must have been completed.
. Adjustments of this unit are made by extended connection of each plug-in board. Be sure to turn off the
power before disconnecting the board.
HXCU-100
Section 6

Electrical Alignment

Use
Front/rear-side vertical extended board (long size)
Front-side horizontal extended board
Front/rear-side vertical extended board (short size)
Rear-side horizontal extended board
6-1 (E)