8. Remove the clamp fi lter 1 from the FL
shield.
9. Disconnect the coaxial cable from the
connector CN2 on the FL-349 board, and
pull it out of the hole in the FL shield.
n
Be sure to hold the plug when disconnect-
ing the coaxial cable. Do not pull the cable.
10. Remove the TRIAX connector assembly.
(Refer to Section 5-4.)
11. Remove the three screws to remove the
FL-349 board.
12. Remove the clamp fi lter 2.
13. Install a new FL-349 board by reversing the
steps above.
n
Hold the plug of the coaxial cable, and
connect it perpendicularly to the connector.
Push the plug into the connector while turn-
ing it clockwise and counterclockwise
several times.
HXCU-100
PSW3 x 6
FL-349
board
FL shield
Hold the plug to remove.
OK
Hold the plug to connect.
CN2
Clamp filter 2
Coaxial cable
Clamp filter 1
Do not attempt to remove by
NG
pulling the cable.
Connecting
connector
5-11 (E)