1-7.

Potentiometer Functions

DPR-300 Board
G
F
E
D
11
LV1501
RV1501
1
LV1502
1
RV1502
1 1
RV1503
LV1503
DPR-300 Board (SIDE A)
Ref.No.
Name
RV1501
DEV ADJ
RV1502
ST INCOM LEV ADJ
RV1503
TONE ADJ.
RV2601
DC (Position)
RV2602
LEVEL (Interval)
LV1501
1.0M FREQ ADJ
LV1502
TUNE 1
LV1503
TUNE 2
SY-364 Board
RV1
1
L
K
J
H
G
F
SY-364 Board (SIDE A)
Ref.No.
Name
RV1
27M FREQ
RV530
PROD RTS CANCEL
RV531
ENG RTS CANCEL
1-12 (E)
C
B
A
1
RV2602
1
2
1
RV2601
3
4
5
6
Description
Adjusts modulation degree of standby INCOM (CCU to CAM) FM-modulated wave
output.
Adjusts waveform level of standby INCOM (CAM to CCU) demodulation output.
Adjusts free-running oscillation frequency of the TONE signal detection circuit.
Adjusts lateral display position of tri-waveform display on the waveform monitor.
Adjusts display position interval of tri-waveform display on the waveform monitor.
Adjusts modulation frequency of standby INCOM (CCU to CAM) FM-modulated
wave.
Adjusts operating point of the standby INCOM (CAM to CCU) demodulation circuit.
Adjusts output distortion of the standby INCOM (CAM to CCU) demodulation
circuit.
9
8
7
6
1
RV531
5
1
RV530
4
3
2
1
E
D
C
B
A
Description
Adjusts free-running oscillation frequency of 27M-VCO (X1) for readjustment required
when it is replaced.
Adjusts sidetone cancellation amount of the producer line when RTS or Clear-Com
is connected.
Adjusts sidetone cancellation amount of the engineer line when RTS or Clear-Com
is connected.