3-4-4. VBS Signal Level Adjustment

Adjust the VBS signal level that is output from this unit using the color-bar signal.

Adjustment Procedure

Adjust the VBS signal level with VBS LEVEL of M05:ANALOG VIDEO2 in the MAINTENANCE
menu.
Equipment:
SD waveform monitor
Test Point:
VBS connector/SDI-97 board
Specifi cation: A = 140 ?1 IRE (75 Z termination)
B = 1000 ?7 mV p-p (75 Z termination)
NTSC

3-4-5. Waveform Monitor Signal Level Adjustment

The video output signal of the unit can be checked using the waveform monitor connected to the WF
connector. Adjust the WF output signal level using the color-bar signal.

WF Output Signal Level Adjustment Procedure

Adjust the WF output signal level with WF LEVEL of M05:ANALOG VIDEO2 in the MAINTENANCE
menu.
Equipment:
SD waveform monitor
Test Point:
WF connector/CN-3080 board
Specifi cation: A = 140 ?1 IRE (75 Z termination)
B = 1000 ?7 mV p-p (75 Z termination)