6-5. Elevator Cam Replacement
Outline
Replacement
Removing the pinch limiter assembly
Replacing the elevator cam
Reattaching the pinch limiter assembly
Adjustment after replacement
Chacking the tape path adjustment
Note
Prepare two kinds of new stop washers when replacing the elevator cam.
Stop washer (1.5) : 3-669-465-01 x 1 (for mounting the pinch limiter assembly)
Stop washer (2.3) : 3-669-596-01 x 1 (for mounting the elevator cam)
Preparation
1. Set the unit to the unthreading end status.
2. Power off the unit.
3. Remove the top panel. (Refer to Section 2-7-1.)
4. Remove the cassette compartment. (Refer to Section 2-8.)
Tools
. Washer extracting fixture (A) :
. Washer mounting fixture Ø1.5 :
. Cleaning cloth :
. Cleaning fluid :
. Grease (SGL-941) :
. Tweezers
6-14
J-6082-234-A
J-6082-231-A
3-184-527-01
9-919-573-01
7-662-001-39
HVR-1500