8-3-2. HCK Frequency Adjustment
(Connection)
HVR-1500
TP
Conditions for adjustment
. Extension of the AVP-7 board.
(Refer to Section 2-15.)
. STOP mode
. Front panel
VIDEO INPUT SELECT: COMPOSITE
. Rear panel
REF. VIDEO IN: No signal
VIDEO IN: No signal
8-3-3. HD HCK Frequency Adjustment
(Connection)
HVR-1500
TP
Conditions for adjustment
. Extension of the AVP-7 board.
(Refer to Section 2-15.)
. STOP mode
. Front panel
VIDEO INPUT SELECT: COMPOSITE
. Rear panel
REF. VIDEO IN: No signal
VIDEO IN: No signal
8-4
Oscilloscope
Frequency counter
Measurement point, Specification
P151/AVP-7 (A-8)
Spec. : f = 27,000,000 ± 10 Hz
Oscilloscope
Frequency counter
Measurement point, Specification
TP151/AVP-7 (A-8)
59.94 Hz mode
Spec. : f = 37,087,912 ± 10 Hz
50 Hz mode
Spec. : f = 37,125,000 ± 10 Hz
Adjustment
. MENTENANCE MENU
(Refer to Section 4-2-2.)
ELECTRICAL ADJUST
↓
AVP BOARD ADJ
↓
CLK 27MHz INT ADJ
Adjustment
. MENTENANCE MENU
(Refer to Section 4-2-2.)
ELECTRICAL ADJUST
↓
AVP BOARD ADJ
↓
CLK 74/2MHz INT ADJ