C11A5: Saddle In & Out Guide Motor Failure; C11A6: Saddle Layable Guide Drive Failure - Konica Minolta bizhub C353 Service Manual

Field service
Hide thumbs Also See for bizhub C353:
Table of Contents

Advertisement

9. Malfunction code
9.2.3
C11A5: Saddle in & out guide motor failure
In & out guide motor (M13)
In & out guide home sensor (PS23)
1
Step
Check the M13 connector for proper con-
1
nection and correct as necessary.
Check M13 for proper drive coupling and
2
correct as necessary.
3
M13 operation check
4
PS23 I/O check, sensor check
5
Change SDCB
9.2.4

C11A6: Saddle layable guide drive failure

Layable guide motor (M14)
Layable guide home sensor (PS24)
1
Step
Check the M14 connector for proper con-
1
nection and correct as necessary.
Check M14 for proper drive coupling and
2
correct as necessary.
3
M14 operation check
4
PS24 I/O check, sensor check
5
Change SDCB
44
1
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 2.0 Jan. 2008
SD control board (SDCB)
WIRING DIAGRAM
Control signal
SDCB PJ4-4 to 5
SDCB PJ10-3 (ON)
SD control board (SDCB)
WIRING DIAGRAM
Control signal
SDCB PJ4-8 to 9
SDCB PJ10-6 (ON)
Location
(Electrical
component)
SD-505 G-6
SD-505 B-2 to 3
Location
(Electrical
component)
SD-505 G-5
SD-505 B-3