Procedure 2 Diagnostic Test Program Execution Check - Toshiba PORTEGE R830 Maintenance Manual

Personal computer
Hide thumbs Also See for PORTEGE R830:
Table of Contents

Advertisement

Troubleshooting Procedures

2.5.2 Procedure 2 Diagnostic Test Program Execution Check

Insert the Diagnostics Disk (CD) in the ODD, turn on the computer and run the test. Refer to
Chapter 3, Tests and Diagnostics, for more information about the diagnostics test procedures.
Make sure the floppy disk is formatted correctly and that the write protect tab is disabled.
Floppy disk drive test error codes and their status names are listed in Table 2-7. If any other
errors occur while executing the FDD diagnostics test, go to Check 1.
Code
Check 1
If the following message is displayed, disable the write protect tab on the floppy
disk by sliding the write protect tab to "write enable". If any other message appears,
perform Check 2.
Write protected
Check 2
Make sure the floppy disk is formatted correctly. If it is, go to Procedure 3.
2-32
PORTEGE R830 Satellite R830 Series Maintenance Manual (960-880) [CONFIDENTIAL]
Table 2-5 FDD error code and status
Status
01h
Bad command
02h
Address mark not found
03h
Write protected
04h
Record not found
06h
Media replaced
08h
DMA overrun error
09h
DMA boundary error
10h
CRC error
20h
FDC error
40h
Seek error
60h
FDD not drive
80h
Time out error (Not ready)
EEh
Write buffer error
FFh
Data compare error

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Satellite r830

Table of Contents