GBC Orca 1600 Operation And Maintenance Manual page 45

Orca 1600 laminators
Table of Contents

Advertisement

Installation
b) Open the control side cabinet by removing the
four hex button head screws with a 5/32 in. allen
wrench.
B o lts
4
O
1
I
U
N
T
P
P
U
U
3
T
T
2
4
O
1
I
U
N
T
P
P
U
U
3
T
T
2
+
-
L in e te rm in a l b lo c k
c) Remove the power cable strain relief ( 175-201 )
from the accessory box and install it at the lower
rear hole of the control side cabinet.
d) Connect the power cord to the line terminal
block. Refer to the correct Figure for your
connection. Jumper bars may require removing
or cutting.
R ed W ires
L 6 L 4 L 2 L 5
Jum per B ars
Page 4 - 10
S tra in re lie f
Blue W ires
L 3
L 1
G ound
W ire
Orca 1600 Operation and Maintenance Manual
Figure 4.7.1 Single phase ( 3 wire )
R ed W ires
L 6 L 4 L 2 L 5 L 3
H ot Leg
Figure 4.7.2 Delta three phase ( 4 wire )
C ut here
Jum per
Bar
Terminal
R ed W ires
connecter
Position
Jum per Bars
H ot Leg
Jum per W ire
Figure 4.7.3 Wye three phase ( 5 wire )
R ed W ires
L 6 L 4 L 2 L 5 L 3
R emove
Jump er Bars
H ot Le g
H ot Le g
© GBC Films Group February 2001
B lu e W ires
L 1
G ound
W ire
G rou nd
H ot Leg
Blue W ires
L 6 L 4 L 2 L 5 L 3 L 1
G round
H ot Leg
H ot Leg
Blue W ire s
L 1
G ro und
H ot Le g
N eutral Leg
G ound
W ire
G oun d
W ire

Advertisement

Table of Contents
loading

Table of Contents