GBC Orca 1600 Operation And Maintenance Manual page 20

Orca 1600 laminators
Table of Contents

Advertisement

Orca 1600 Operation and Maintenance Manual
IN F O R M AT IO N
T op tem perature control unit on/ off
sw itch m ust be on to turn the low er
tem perature control unit to on.
IN F O R M AT IO N
W hen decreasing pressure, allow the
pressure guage to drop below the desired
value, then increase pressure to the set
pressure desired. T his allow s for a m ore
accurate pressure reading.
IN F O R M AT IO N
W hen an em ergency stop feature is activated
and the m ain roll is in the up position, the
pull roll w ill only stay in the up position
until the em ergency stop feature is
deactivated.
IN F O R M AT IO N
T he m otor m ust be engaged for the cooling
fans to turn on. If the fan sw itch is in the
"on" position, the fans w ill autom atically
turn on w hen the m otor is engaged.
© GBC Films Group February 2001
IN F O R M AT IO N
W hen requiring top and bottom heat, it is
recom m ended to set both tem peratures to
the sam e set point.
IN F O R M AT IO N
T he m axim um set point tem perature
o
is 270
F ( 132
IN F O R M AT IO N
T he m inim um set point tem perature
o
is 32
F ( 0
IN F O R M AT IO N
W hen a safety feature is engaged, the
upper rollers raise and pow er to
the drive m otor is rem oved.
IN F O R M AT IO N
T he upper m ain roller U P/ D O W N sw itch
resets the m ain roller to the correct position.
Safety
o
C ).
o
C ).
Page 1 - 9