Control Board Fuse Replacement

The Control Board used in this appliance (SIT Proflame 2) has
one fuse that could potentially need replacement. See spec sheet
for fuse or contact your Montigo Dealer.
1). Disconnect the Electrical and Gas supply to the appliance.
2). Remove the Front Faceplate from the appliance.
3). The Fuse is in a plastic retainer, located on the right side of the
Control Board. The Plastic Retainer plugs into the Control Board as
a Cable End would. You may have to gently use a screw driver to
wiggle this away from the Control Board.
Figure 78 Sec.10
4). Remove and replace the Fuse from the Plastic Retainer.
Figure 79 Sec.10
XG0514-092314
Maintenance
Figure 80 Sec.10
4). Re-install the Plastic Retainer into the Control Board.
5). Re-install the Front Faceplate.
6). Re-connect Electrical and Gas supply to the appliance.
I-Series Indoor Gas Fireplace