9). Attach the label provided to the side of the valve body. This
label shows that the valve has been converted using SIT approved
components.
Figure 10 Sec.6
10). Run the cable from the stepper motor in between the control
mounting bracket and fireplace.
Figure 11 Sec.6
12). Plug the cable into the control board.
Figure 12 Sec.6
XG0513-092314
Installation
13). Reinstall the 2 screws to secure the top of the control board
mounting bracket. Using the zip strap supplied, secure the excess
of wires neatly within the control / valve area. Re-install the 2
screws that keep the valve body from swinging out from the unit.
When swinging valve back in use care to not pinch or kink
wires or pilot gas line. Inspect pilot gas line for leaks.
Figure 13 Sec.6
Converting the main burner orifice to LP
14). Remove burner, see burner removal section. Using a socket
wrench and driver, loosen and remove the main burner orifice.
Figure 14 Sec.6
15). Place the LP main orifice into the end of the socket wrench.
Being sure not to cross thread the orifice, install the orifice into
the mounting within the air shutter box.
Figure 15 Sec.6
I-Series Indoor Gas Fireplace