Montigo 30FID Installation & Maintenance Manual page 59

I-series indoor residential fireplace insert
Table of Contents

Advertisement

13). Install the replacement Components in the reverse order, through
the Firebox wall. Install the Pilot Assembly Bracket to the Firebox
floor with 2 screws. Pass the wires through rubber gasket. Make
sure the pilot gas line goes through the far right hole of the gasket
and the cuts in the gasket face up. Make sure that the Ground Wire,
Star Washer and screw are assembled to the bottom of the Pilot
Mounting Bracket as shown in the picture below.
Figure 67 Sec.10
Figure 68 Sec.10
14). Using a round object, like a socket wrench, loop the excess pilot
line into a coil. Be very careful to not kink the line.
Figure 69 Sec.10
XG0514-092314
Maintenance
15). Attach the Pilot line back into the valve, being very careful not
to over-tighten the line.
16). Feed the 2 electrical wires in between the shell of the unit and
the Control Board and plug them into the appropriate terminals on
the control board.
17). Tie up excess wires and zap strap. Take care to not pinch or
kink wires and pilot gas line.
Figure 70 Sec.10
18). Reverse these steps for reinstallation. Re-connect Gas and
Electrical supply.
I-Series Indoor Gas Fireplace
Page 59

Advertisement

Table of Contents
loading

This manual is also suitable for:

34fid - linear30fid-linear

Table of Contents