3). Using a T20 Torx screw driver, remove the 2 screws that attach
the stepper motor to the valve.
Figure 4 Sec.6
4). Remove the screws, stepper motor and rubber diaphragm.
Figure 5 Sec.6
5). Remove the top 2 screws that hold the control mounting
bracket in place.
Figure 6 Sec.6
Page 18
Installation
6). Unplug the cable that runs from the stepper motor to the control
board and remove it from in between the control board mounting
bracket and the fireplace.
Figure 7 Sec.6
7). Place the LP stepper motor onto the valve being extremely
careful that the orientation of the regulator is correct.
Figure 8 Sec.6
8). Reinstall the 2 screws supplied with the conversion kit to fasten
the stepper motor to the valve body.
Figure 9 Sec.6
XG0513-092314