Control Board Fuse Replacement

The Control Set used in this appliance (SIT Proflame 2) has one
fuse that could potentially need replacement. See spec sheet for
fuse or contact your Montigo Dealer.
1). Disconnect the Electrical and Gas supply to the appliance.
2). Remove the Front Faceplate from the appliance.
3). The Fuse is in a plastic retainer, located on the right side of the
Control Board. The Plastic Retainer plugs into the Control Board as
a Cable End would. You may have to gently use a screw driver to
wiggle this away from the Control Board.
Figure 73 Sec.10
4). Remove and replace the Fuse from the Plastic Retainer.
Figure 74 Sec.10
Page 64
Maintenance
Figure 75 Sec.10
4). Re-install the Plastic Retainer into the Control Board.
5). Re-install the Front Faceplate.
6). Re-connect Electrical and Gas supply to the appliance.