I-Series Indoor Gas Fireplace
7). Remove the 2 screws securing the pilot bulk head plate and
gasket to the firebox wall. The gasket may be stuck to the wall and
may need to be pried
Figure 61 Sec.10
8). Remove the screws securing the valve mounting bracket. Swing
valve out. Disconnect the pilot line from the bottom of the gas valve.
Figure 62 Sec.10
9). Remove the 2 screws securing the top of the control mounting
bracket to the outer shell of the fireplace.
Figure 65 Sec.10
Page 58
Maintenance
10). Disconnect both the ignition wire and the flame sensor wire from
the control board.
Figure 64 Sec.10
11). Feed the 2 electrical lines from the control board to the side of
the unit.
Figure 63 Sec.10
12). From the inside of the firebox, pull the pilot assembly, bulk head
plate, gasket and 3 lines through the firebox and out of the unit. Leave
the ground wire in the firebox.
Figure 66 Sec.10