Montigo 30FID Installation & Maintenance Manual page 20

I-series indoor residential fireplace insert
Table of Contents

Advertisement

I-Series Indoor Gas Fireplace
Converting the pilot burner orifice to LP
16). Remove the spring clip that retains the Pilot Flame Hood.
Figure 16 Sec.6
17). Remove the pilot hood from the pilot assembly
Figure 17 Sec.6
18). Using an Allen key, remove the NG Pilot Orifice
Figure 18 Sec.6
Page 20
Installation
19). Replace the NG Pilot orifice with the LP Pilot orifice. If you
get the orifices mixed up, the LP orifice has a grove machined
around the diameter near the end.
Figure 19 Sec.6
20). Reverse steps to install pilot hood.
21). The minimum primary air setting is different depending on fuel
and burner. The minimum primary air is set by hand-bent tabs on
the primary air adjustment. Bend the appropriate tab down for your
fuel and burner. See specifications table or primary air adjustment
for proper tab. See image below for tab lengths. If your setting is
fully closed, bend both tabs up.
Figure 20 Sec.6
3/16 "
1/16 "
XG0513-092314

Advertisement

Table of Contents
loading

This manual is also suitable for:

34fid - linear30fid-linear

Table of Contents