Control Board Fuse Replacement - Montigo 34FIDN-S-F [NG] Installation And Maintenance Manual

I-series indoor residential fireplace insert
Hide thumbs Also See for 34FIDN-S-F [NG]:
Table of Contents

Advertisement

Control Board Fuse Replacement

The Control Set used in this appliance (SIT Proflame 2) has one
fuse that could potentially need replacement. See spec sheet for
fuse or contact your Montigo Dealer.
1). Disconnect the Electrical and Gas supply to the appliance.
2). Remove the Front Faceplate from the appliance.
3). The Fuse is in a plastic retainer, located on the right side of the
Control Board. The Plastic Retainer plugs into the Control Board as
a Cable End would. You may have to gently use a screw driver to
wiggle this away from the Control Board.
Figure 73 Sec.10
4). Remove and replace the Fuse from the Plastic Retainer.
Figure 74 Sec.10
XG0508-
150204
Maintenance
Figure 75 Sec.10
4). Re-install the Plastic Retainer into the Control Board.
5). Re-install the Front Faceplate.
6). Re-connect Electrical and Gas supply to the appliance.
I-Series Indoor Gas Fireplace
Page 61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

34fidl-s-f [lp]

Table of Contents