Redundancy Status; Monitoring Temperatures Of Modules - Juniper E-Series Installation And User Manual

Juniper router installation and user guide
Hide thumbs Also See for E-Series:
Table of Contents

Advertisement

Table 10-4 Troubleshooting abnormal LED activity on modules (continued)
Diagnostic Signs
None

Redundancy Status

Monitoring Temperatures of Modules

Possible Problems
System temperature is
too high.
Vents are blocked.
Fans are not operating.
You can determine the redundancy state of line modules by examining
the online and redundant status LEDs (ERX-7xx/14xx models only). See
Table
10-5.
Note: The REDUNDANT LED on the
modules is nonfunctional.
OCx/STMx
Table 10-5 Redundancy status of a line module
ONLINE LED
REDUNDANT LED State of the Line Module
Off
Off
On
Off
Off
On
On
On
You can view the temperature of each module by issuing the show
environment all and show environment table commands. In
addition, the system generates detailed log messages if the temperature of
a module is outside normal operating limits.
If the temperature of any module exceeds the upper temperature limit,
the system immediately goes into thermal protection mode. Once the
system has entered thermal protection mode, you must resolve the cause
of the high temperature.

Monitoring Temperatures of Modules

Actions
1 Check your console for a message indicating the
problem. If you have the system log set to a severity
of WARNING or higher, a Warning message
indicating the failure is displayed.
2 Issue the show environment command to display
the temperatures. If the temperature is too high,
power down the system.
3 Regulate temperature.
4 Reset system.
cOCx/STMx, FE-8, GE/FE, HSSI, and
Module is booting or is an inactive primary line
module.
Module is active, but no standby module is
available.
Module is in standby state.
Module is active, and a standby module is
available.
10-9
E-Series Routers

Advertisement

Table of Contents
loading

Table of Contents