Ê Lower the lifter platform and slide the server into the rack (4). Remove the
lifter.
Ê Fasten the server to the rack with the four knurled screws on the front panel
and the cage nuts (5).
Ê Route the cables as described in the Technical manual for the rack in
question.
V
CAUTION!
Never lift or transport the server using the handles on the front panel as
they are not designed to bear the weight of the server.
The front handles are only to be used for pushing the server into the rack
or pulling it out of the rack.
5.2.3

Installation in 3rd party racks

I
The rails from Fujitsu are suitable for use in any 3rd party racks for
standard servers (installation depth 714 - 785 mm) without restrictions.
Ê Refer to the manual from the rack manufacturer for details of the mechanical
installation and the climatic conditions.
V
CAUTION!
When installing in 3rd party racks, it must be ensured that an air flow
from the front to the back of the rack is guaranteed.
Ê Fit the required original parts (support bracket or cable management
system).
I
Under certain circumstances, you will not be able to use some of the
parts from the rack installation kit supplied - you will need to use
original 3rd party rack parts instead.
Racks with installation depth of 735 mm
The lengths of the rails do not need to be adjusted with respect to each other
for the installation in rack systems with 735 mm installation depth.
Ê Secure the rails as described in section
page
63.
RX900 S2
"Installing the rail in the rack" on
Operating Manual
Hardware installation
67