Installing/Removing The Server In/From The Rack; Rack System Requirements - Fujitsu Primergy RX900 S2 Operating Manual

Fujitsu primergy rx900 s2 server operating manual
Hide thumbs Also See for Primergy RX900 S2:
Table of Contents

Advertisement

5.2
Installing/removing the server in/from the
rack
V
CAUTION!
Please observe the safety information and notes on rack mounting in
chapter
At least two people and a suitable lifter are required to install/remove
the server in/from the rack. (For the Japanese market, please refer to
" 安全上の注意およびその他の重要情報 ".)
The rack may tip over if more than one unit is removed at the same
time.
The server may not occupy the top height units of the rack
(38HU/42HU PRIMECENTER Rack, DataCenter Rack, 19-inch
standard rack (for the Japanese market)), as otherwise boards
cannot be replaced.
5.2.1

Rack system requirements

The rack systems from Fujitsu PRIMECENTER Rack, DataCenter Rack and
19-inch standard rack (for the Japanese market) support the installation of
PRIMERGY servers. Installation in most current rack systems from other
manufacturers (3rd party racks) is also supported.
To accommodate the ventilation concept and ensure proper ventilation, any
unused areas in the rack must be sealed using dummy covers.
The power is supplied via the multiple socket outlets fitted in the rack.
Fujitsu rack systems
The main features of PRIMECENTER Rack, DataCenter Rack and 19-inch
standard rack (for the Japanese market) are as follows:
– support systems having a linear alignment feature to ensure that they can
be adjusted to different rack depths
PRIMECENTER Rack and DataCenter Rack provide an enhanced cable
management in the lateral rack area.
RX900 S2
"Important information" on page
Operating Manual
Hardware installation
39.
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents