9.2

Hot-plug fans

The server comes with four hot-plug fans in 3+1 redundant configuration. The
fans are mounted in a fan cage that is accessible from the top when removing
the fan cover. For information on removing the fan cover and replacing a
defective fan see "PRIMERGY RX900 S2 Server Upgrade and Maintenance
Manual".
A possible fan failure is reported by the CSS indicator lighting up on the front
and rear of the server as well as by the indicator (1) on the fan module in
question, see
figure
The fan failure is also displayed on the ServerView Local Service Display, see
the "Customer Self Service (CSS)" manual on the ServerView Suite DVD 2.
Figure 20: Indicators on the fan module
Pos. Description
1
Indicator on hot-plug fans (orange)
– Lights up orange if a fan has failed.
9.3

Hot-plug HDD/SSD modules

The hard disk drives and solid state drives which can be ordered for the
PRIMERGY RX900 S2 are supplied already mounted in an installation frame so
that defective drives can be replaced and new drives can be added during
operation. The hard disk drive/solid state drive and the installation frame
together make up the HDD/SSD module.
For information on installing or replacing HDD/SSD modules see "PRIMERGY
RX900 S2 Server Upgrade and Maintenance Manual".