Fujitsu Primergy RX900 S2 Operating Manual page 89

Fujitsu primergy rx900 s2 server operating manual
Hide thumbs Also See for Primergy RX900 S2:
Table of Contents

Advertisement

System already installed:
Ê Press the On/Off button (see figure
The server is switched on, performs a system test and boots the
operating system.
Switching the server off
The power-on indicator lights up green (see figure
Ê Shut down the operating system properly.
The server is switched off automatically and goes into standby mode. The
power-on indicator lights up orange.
I
If the operating system does not switch the server off automatically, press
the On/Off button for at least four seconds and/or send a corresponding
control signal.
Other On/Off options
Besides the On/Off button, the server can be switched ON and OFF in the
following ways:
– Timer-controlled switch-on/off
Using the ServerView Operations Manager or iRMC S2, you can configure
that the server is switched on/off controlled by timer.
– Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet
– After power failure
The server automatically reboots following a power failure (depending on the
settings in the BIOS or in iRMC S2).
– Power button override
The system can be switched off by pressing and holding down the On/Off
button (for approximately 4 - 5 seconds).
V
CAUTION!
There is a risk that data may be lost.
RX900 S2
15 on page
Operating Manual
Starting up and operation
78).
15 on page
78).
TM
).
89

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents