Functional overview
Ambient conditions
Environment class 3K2
Environment class 2K2
Temperature:
Operation (3K2)
Transport (2K2)
Humidity
Condensation during operation must be avoided!
Ventilation clearance
At least 200 mm on the front and rear.
Electrical values
Power supply
configuration
Max. output of single
power supply
Hot-plug power supply
redundancy
Rated voltage range
Rated frequency range
34
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
10 °C .... 35 °C
-25 °C .... 60 °C
10% ... 85% (non condensing)
– Up to 4 hot-plug power supply units
– Base unit equipped with 2 power supply units
– Redundancy concept only applicable for the
mains voltage 200 - 240 V: Basic configuration:
1+1 redundancy; AC redundancy available with
a 1+1 or 2+2 redundant configuration.
2000 W
Yes
100 - 240 V
50 - 60 Hz