IBM Infoprint 1130 Service Manual page 45

Hide thumbs Also See for Infoprint 1130:
Table of Contents

Advertisement

IBM Infoprint 1130/1140
First 6
Bytes Sub
Error Code
Data - Note:
xx can be
any value
EN 41 xx yy
-- 1
EN -- zz -- --
2
922 Service - Fuser Error (Fuser failed to reach standby temperature)
EN 42 xx yy
-- 1
EN z1 z2 -- -
- 2
923 Service - Fuser Error (Fuser over temperature)
EN 12 xx yy
-- 1
EN -- -- -- --
2
924 Service - Fuser Error (Open Thermistor Failure)
EN 18 xx -- -
- 1
EN -- 00 -- --
2
2-18
Service Manual
Explanation
xx=Actual Fuser Temperature
yy=The temperature that the fuser wants to reach.
zz=00 The fuser temperature did not change enough from the
fuser lamp temperature at turn on.
01 The fuser temperature rose more than desired from the
fuser temperature at turn on.
xx=Actual Fuser Temperature
yy=The temperature that the fuser wants to reach.
zz=00 The fuser temperature did not change enough from the
fuser lamp temperature at turn on.
01 The fuser temperature rose more than desired from the
fuser temperature at turn on.
z2=00 The Hot Roll did not reach standby temperature in time
during standby.
01 The Hot Roll took too long to reach the beginning lamp
detection temperature.
02 The Hot Roll reached 'final lamp detection
temperature' but took longer than expected.
03 The Hot Roll timed out trying to reach the 'final lamp
detection temperature.'
04 After Hot Roll lamp detection, did not reach steady
state control in time.
05 The Hot Roll did not reach operating temperature in
time.
This sub error code is displayed anytime that the Hot Roll has
reached a higher than desired temperature.
xx=Actual Fuser Temperature
yy=The temperature that the fuser wants to reach.
This code is usually generated when an open circuit check is
made of the thermistor circuit in the fuser.
xx=Actual Fuser Temperature

Advertisement

Table of Contents
loading

This manual is also suitable for:

Infoprint 1140