Configuration Menu - IBM Infoprint 1130 Service Manual

Hide thumbs Also See for Infoprint 1130:
Table of Contents

Advertisement

IBM Infoprint 1130/1140
Tests
EP Setup
If selected, the following menu selections are
available:
1.EP Defaults
2.Fuser Temperature
3.Warm Up Time
4.Transfer
5.Print Contrast
6.Charge Roll
7.Gap Adjustment (envelope solenoid)
Error Log
If selected, the following menu selections are
available:
1.Display Log
2.Clear Log
Exit Diagnostics

Configuration Menu

Maintenance Count Value (Viewable only)
Reset Maintenance Count
Print Quality Test Pages
Download Emuls (only displayed if at least
one downloaded emulator is installed)
Factory Defaults
Exit Configuration Menu
To run the printer diagnostic tests described in this chapter, you must
put the printer in Diagnostic Mode.
Refer to Test Page
"Restore EP Factory
Defaults" on page 3-32
"Error Log" on
page 3-13
"Exiting the
Diagnostics Mode" on
page 3-6
"Maintenance Page
Count" on page 3-31
"Setting the Page
Count" on page 3-30
"Print Quality Test
Pages" on page 3-34
"Disabling Download
Emulations" on
page 3-8
"Restore EP Factory
Defaults" on page 3-32
Press Select to go to
Configuration Menu
Diagnostic Aids