Output Bin - Feed To All Bins Test - IBM Infoprint 1130 Service Manual

Hide thumbs Also See for Infoprint 1130:
Table of Contents

Advertisement

IBM Infoprint 1130/1140
The multipurpose tray and the envelope feeder do not have a paper
low sensor. The multipurpose tray does not have a pass thru sensor.
The following tray sensors are supported by this test:
Source
Tray 1
Tray 2
Tray 3
Tray 4
Tray 5
Multipurpose
Tray
Envelope Feeder

Output Bin - Feed to all Bins Test

This test can be used to verify that the printer can feed media to the
standard bin or any installed output options. No information will be
printed on the test pages as the printhead is not turned on during the
feed test.
To run the Feed to all Bins Test:
1. Select Feed to all Bins Test from the Menu.
2. The media feeds from the default paper source.
3. The printer feeds a separate piece of media to the standard bin
first, then it feeds a separate piece of media to each output bin
installed in the following order:
First Sheet: Standard Bin, Second Sheet: Bin #1, Third Sheet:
Bin #2, Fourth Sheet: Bin #3, Fifth Sheet: Bin #4, Sixth Sheet:
Bin #5, Seventh Sheet: Bin #6, Eighth Sheet: Bin #7, Ninth
Sheet: Bin #8, Tenth Sheet: Bin #9, Eleventh Sheet: Bin #10,
3-20
Service Manual
Tray Empty
Sensor
YES
YES
YES
YES
YES
YES
YES
Paper Low
Sensor
YES
YES
YES
YES
YES
NO
NO
Pass Thru
Sensor
NO
YES
YES
YES
YES
NO
YES

Advertisement