Optical Disk Drive Troubleshooting; Procedure 1 Diagnostic Test Program Execution Check; Procedure 2 Connector Check And Replacement Check - Toshiba TECRA A11 Series Maintenance Manual

Personal computer
Hide thumbs Also See for TECRA A11 Series:
Table of Contents

Advertisement

2.10 Optical Disk Drive Troubleshooting

To check if optical disk drive is malfunctioning or not, follow the troubleshooting procedures
below as instructed.
Procedure 1:
Procedure 2:

2.10.1 Procedure 1 Diagnostic Test Program Execution Check

Execute the CD-ROM/DVD-ROM Test in the Diagnostic Program. Refer to Chapter 3, Tests
and Diagnostics for more information on how to perform the test program.
Prepare the tools before the test.
If any error is detected by the test, go to Procedure 2.

2.10.2 Procedure 2 Connector Check and Replacement Check

The SATA ODD may be disconnected, or the SATA ODD or system board may be damaged.
Disassemble the computer following the steps described in Chapter 4, Replacement
Procedures and perform the following checks:
Check 1
Make sure the SATA ODD is firmly connected to CN1950 on the system
board.
If any of the connections are loose, reconnect firmly and repeat Procedure 1. If
there is still an error, go to Check 2.