Omron JZA User Manual page 91

Compact general purpose inverter 200 v class three-phase input 0.1 to 0.4 kw 200 v class single-phase input 0.1 to 1.5 kw 400 v class three-phase input 0.2 to 4.0 kw
Hide thumbs Also See for JZA:
Table of Contents

Advertisement

No.
E2-05
Note: The setting range becomes 0.00 to 130.00 when using JZAB0P2, JZA20P2, JZA40P2 and smaller.
Contact the motor manufacturer to find out the line-to-line resistance or measure it manually. When using the manufacturer
Motor Test Report, calculate E2-05 by the formulas below.
• E-type insulation: Multiply 0.92 times the resistance value (Ω) listed on the Test Report at 75 °C
• B-type insulation: Multiply 0.92 times the resistance value (Ω) listed on the Test Report at 75 °C.
• F-type insulation: Multiply 0.87 times the resistance value (Ω) listed on the Test Report at 115 °C.
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
Parameter Name
Motor Line-to-Line Resistance
5.5 E: Motor Parameters
Setting Range
Depending on
0.000 to 65.000 Ω
Default
o2-04
5