Documentation Supplied; Supporting Documentation; Product Structure; Specifications - HP 7936 Support Manual

Disc drives
Table of Contents

Advertisement

Product Information
7936 and 7937
1-3.
DOCUMENTATION SUPPLIED
The drive is supplied with one each of the follow-
ing publications:
H P
7936
and
H P
7937
Disc
DrivC.'s
Operating and Installation Manual, part no.
07937-90902
Site
Environmental
Requirements
lor
Disc/Tape Drives Manual, part no. 5955-3456
1-4.
SUPPORTING DOCUMENTATION
The following supporting documentation for the
drive
may
be
ordered
from
your
nearest
Hewlett-Packard Sales and Support Office:
HP
7936
and
HP
7937
Hardware
Support
Manual,
07937-90903
Disc
Drives
part
no.
CS/80 Instruction Set Programming Manual,
part no. 5955-3442
CS/80 External Exerciser Manual, part no.
5955-3462
1-5.
PRODUCT STRUCTURE
The drive product structure is outlined in Table
1-1.
1-6.
SPECIFICATIONS
Specifications for the drive are listed in the Site
Environmental Requirements lor Disc/Tape Drives
Manual, part no. 5955-3456. This manual is sup-
plied with the drive.
1-7.
SERIAL NUMBER
The serial number of the drive is recorded on a
serial number label attached to the front cover of
the drive, below the front panel. The drive model
1-2
number and full serial number should be quoted in
any communication with Hewlett-Packard regard-
ing the drive.
1-8.
SUPPORTED EQUIPMENT
This manual is intended to provide the informa-
tion needed to support service of the drive and all
of its accessories and options.
1-9.
TEST EQUIPMENT REQUIRED
No special test equipment is needed for installation
and normal maintenance of the drive. However,
when using the special diagnostics available for
troubleshooting the drive, the following equipment
is needed:
HP 85B Personal Computer
CS/80 External Exerciser Tapes, part num-
bers 5010-0566 and 5010-0567.
CS/80 External Exerciser Manual, part no.
5955-3462.
1-10.
WARRANTY
The drive is covered by a 90-day Hewlett-Packard
warranty. However, this warranty is voided if the
sealed head-disc assembly is opened or otherwise
tampered with. The warranty does not include in-
stallation or rack mounting.
1-11.
SUPPORT STRATEGY
The drive may be repaired on site to the field
replaceable assembly level. Troubleshooting is
aided by firmware controlled self -test diagnostics
with the malfunctioning assembly identified on a
front-panel display, error codes returned by the
drive to the CPU, and diagnostics available
through the use of the HP 85B Personal Computer
and an external exerciser or a host-supported ex-
ternal exerciser.