Section 8: Appendix
8.2 OPTIONAL ACCESSORIES - DISPENSER (cont'd)
6.
Attach the latches of the Dispenser kit onto the holes
located below the two sides of platen roller of the printer.
Close the top cover , close the Pressure bracket and turn
the printer over again, with the Main PCB is facing upward.
7.
From the base of the Dispenser kit , secure the cutter unit
to the printer with the supplied screw (circled) as shown.
8.
Connect the Dispenser kit's cable to the OPTION
connector on the MAIN PCB .
Route the Dispenser kit's cable through the groove (cir-
cled) of the printer as shown.
9.
Assemble the Bottom Housing cover back to the printer
and secure with the three screws removed in step 1 .
CAUTION:
Ensure that no cables are pinched between parts when
you are assembling the cover.