Daikin R-410A Service Manual page 369

Sky-air indoor
Hide thumbs Also See for R-410A:
Table of Contents

Advertisement

ESIEN05-04
1.16.6 Removal of Fan Motor
Warning
Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Procedure:
Step
Remove side panels and
other external casing, and
electrical parts box according
to their removal procedures.
1
Loosen the hexagon set
screw fastening the fan
rotor and fan motor.
2
Remove the fan motor
fastener. (3 screws)
3
Remove the fan motor.
Part 5 – Disassembly and Maintenance
Procedure
Disassembly and Maintenance
Points
Use 2.5 mm hexagon nut driver.