Daikin R-410A Service Manual page 280

Sky-air indoor
Hide thumbs Also See for R-410A:
Table of Contents

Advertisement

Disassembly and Maintenance
Step
1
[Installation procedure of
drain pump or float switch]
1
Install a spare drain
pump or float switch on
the mounting plate, then
firmly secure the lead
wires using the provided
clamp materials (3
pieces).
2
Connect the lead wires of
the drain pump or float
switch in the original
state, firmly secure the
aforementioned clamp
3
materials (screw type
fixing) to the drain pan
with the use of mounting
screws.
5 5
5–40
Procedure
Drain pump
Mounting screw
(For float switch)
Float
switch
Float switch
lead wire
Mounting plate
Provided clamp material
(for bundling)
(Fix to the hole in the
mounting plate)
Mounting
screw
Drain
Pan
Engage with the fixing tabs (5 tabs)
Provided mounting screw
(for drain pump)
Provided clamp
material
(for bundling)
Drain pump
lead wire
Clamp material
(for fixing screw)
Part 5 – Disassembly and Maintenance
ESIEN05-04
Points
Pay attention to the mounting
direction of clamp material.
1mm or less
Provided clamp material
(for fixing screw)
(Fix the lead wires each
other.)