Removal Of Horizontal Blade - Daikin R-410A Service Manual

Sky-air indoor
Hide thumbs Also See for R-410A:
Table of Contents

Advertisement

Disassembly and Maintenance

1.11.4 Removal of Horizontal Blade

1
Warning
Procedure:
Step
1
Remove 4 screws each
(16 screws in total) to
dismount the 4 seal
materials.
3
2
Remove 2 screws each
(16 screws in total) to
dismount the 8
horizontal blade
5 5
bearings.
5–28
Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Procedure
Horizontal
blade
bearing
Seal material
Swing motor
Horizontal blade
ESIEN05-04
Points
Reassembling
Make sure that the air outlet
insulation material (seal
material) is as shown below
(may result in dew
condensation).
Air outlet insulation material
Seal
material
No catching or gap is allowed for
the seal material
Part 5 – Disassembly and Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents