Yamaha CE50T Service Manual page 177

Table of Contents

Advertisement

SIGNAL
SYSTEM
Battery fluid specific gravity inspection:
oRecharge battery.
1. Remove caps.
2. Inspectspecific gravity of allcell using Bat- Low specific
Charging Current:
tery Hydrometer.
Iravity (voltage)
0.4 amps/10
hrs
_
NOTE:
Battery
electrolyte
is poisonous
and
Replace the battery if:
dangerous, causing severe burns, etc. It
oBattery voltage will not rise to a
contains sulfuric acid. Avoid contact with
specific value or bubbles fail to
skin, eyes or clothing,
rise even after many hours of
Antidote:
EXTERNAL-Flush
with
water,
charging.
INTERNAL-Drink
large quantities of water
®Sulfation of one or more cells oc-
or milk.
Follow with
milk of magnesia,
curs, as indicated by the plates
beaten egg, or vegetable
oil. Call a physi-
turning white, or an accumula-
clan immediately,
tion of material exists in the bot-
Eyes: Flush with water for 15 minutes and
tom of the cell.
get prompt
medical
attention.
Batteries
oSpecific gravity readings after a
produce
explosive
gases. Keep sparks,
long, slow charge indicate on cell
flame,
cigarettes
etc.,
away.
Ventilate
to be lower than the rest.
when charging
or using in an enclosed
®Warpage or buckling of plates or
space.
Always
shield
your
eyes when
insulators is evident.
working
near batteries.
KEEP OUT OF REACH OF CHILDREN.
Specific Gravity:
1.2804-0.01 at 20°C (68°F)
If there is not Battery Hydrometer, check bat-
tery voltage using Pocket Tester (YU-03112).
1. Remove battery.
2. Set the tester selector to "DC20V"
position.
3. Connect tester leads to battery terminals.
Tester ( + ) lead-_( + ) terminal
Tester (-)
lead--*(- ) terminal
--_
Battery Voltage:
12V or more
'_,/lz OK
6-40